Product Description
Fora P30 Blood Pressure Monitor with Wide range Cuff
Key Features
- l AVG Technology (Automated Averaging of 3 Measurements) conducts THREE measurements within TWO minutes to provide the most accurate and reliable final average test result.
- IRB (Irregular Rapid Beat) Technology: a technology with high precision to detect pulse irregularities during the measurement. It alerts the user of any unusual spikes, patterns and trends for further check-ups with a doctor, but it is not a substitute for a cardiac examination.
- Auscultatory Mode: a multi-purpose device for both patients and professionals
- Smart Memory Function: helps collect various day-time average results (24H/ morning/ evening) to detect morning and evening hypertension
- Clear & Wide Screen View: provides comfort for people of all ages and eyesight quality when reading the results
- Flexible & Easy-Care Wide Range Cuff: one cuff (24-43cm) fits both medium and large arm sizes
- Accuracy by International Protocol: clinical accuracy of the device is further guaranteed by the ESH validation
- Designed by ForaCare Switzerland
- Memory of up to 60 Tests with dates & times
How To Use (Blood Pressure)
Before Measurement
- Sit down for at least 10 minutes before measuring.
- Place your elbow on a flat surface and relax your hand with the palm facing up.
- Apply the proper pressure cuff and make sure the cuff is at the same height as your heart.
Taking Measurements
Single Measurement
- Press to start. Then the cuff will begin to inflate automatically.
- The "heart symbol will flash when a pulse is detected during the inflation.
- After the measurement, the monitor will display the systolic pressure, diastolic pressure and pulse rate
Averaging Measurement (for FORA P30 Plus only)
- Press AVG to start. Then the cuff will begin to inflate automatically.
- The monitor will take 3 measurements consecutively.
- After 3 measurements are completed, the results are averaged and displayed with "AVERAGE symbol" on the monitor
Auscultatory Measurement (Only well- trained staff may use this mode to measure blood pressure manually.)
- Press and hold until "AUS symbol"appears on the display with a beep. The cuff will begin to inflate and then deflate automatically.
- Press AVG to adjust the inflation pressure if necessary, and release AVG to start the measurement.
- The systolic pressure is measured when the operator first hears the sound of the pulse. Then the diastolic pressure is measured until the sound of the pulse disappears.
- The monitor will return to 0 mmHg after the measurement is completed.
Package Content
- Four 1.5V AA alkaline batteries
- 1 Blood pressure machine
- 1 wide range cuff
- Manual instruction